Sigma II User’s Manual
Appendix B: List of Parameters
B - 8
B.2 Switches
The following list shows the switches and their default settings.
Parameter
Digit
Place
Name
Setting
Description
Default
Setting
Pn00
0
Fu
ncti
on Sele
cti
on Basic Switch
es
0
Direction
Selection
0
Sets CCW as forward direction.
0
1
Sets CW as forward direction (reverse rotation
mode).
1
Control Method
Selection
0
Speed control (analog reference).
0
1
Position control (pulse train reference).
2
Torque control (analog reference).
3
Internal set speed control (contact reference).
4
Internal set speed control (contact reference)/Speed
control (analog reference).
5
Internal set speed control (contact reference)/Position
control (pulse train reference).
6
Internal set speed control (contact reference)/Torque
control (analog reference).
7
Position control (pulse train reference)/Speed control
(analog reference).
8
Position control (pulse train reference)/Torque control
(analog reference).
9
Torque control (analog reference)/Speed control
(analog
reference).
A
Speed control (analog reference)/Zero clamp.
B
Position control (pulse tra.in reference)/Position
control (Inhibit)
2
Axis Address
0 to F
Sets servo amplifier axis address.
0
3
Reserved
—
0
Pn
001
F
unction
Sel
ection
Appl
ication
Swi
tche
s
0
Servo OFF or
Alarm Stop
Mode
0
Stops the motor by applying dynamic brake (DB).
0
1
Stops the motor by applying dynamic brake (DB) and
then releases DB.
2
Makes the motor coast to a stop state without using
the dynamic brake (DB).
1
Overtravel
Stop Mode
0
Same setting as Pn001.0 (Stops the motor by
applying DB or by coasting.)
0
1
Sets the torque of Pn406 to the maximum value,
decelerates the motor to a stop, and then sets it to
servo lock state.
2
Sets the torque of Pn406 to the maximum value,
decelerates the motor to a stop, and then sets it to
coasting state.
2
AC/DC Power
Input Selection
0
Not applicable to DC power input: Input AC power
supply through L1, L2, and (L3) terminals.
0
1
Applicable to DC power input: Input DC power supply
through (+)1 and (-) terminals.
3
Warning Code
Output Selec-
tion
0
ALO1, ALO2, and ALO3 output only alarm codes.
0
1
ALO1, ALO2, and ALO3 output both alarm codes and
warning codes. While warning codes are output,
ALM signal output remains ON (normal state).
Summary of Contents for SGMAH
Page 1: ...Sigma II Series Servo System User s Manual...
Page 2: ......
Page 4: ...ii This page intentionally left blank...
Page 6: ...iv This page intentionally left blank...
Page 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Page 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Page 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Page 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Page 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Page 487: ......