Sigma II User’s Manual
Chapter 8: Ratings and Characteristics
8 - 35
*1
Allowable regenerative frequency is the number of times the servomotor is allowed to accelerate and
decelerate through a 0rpm
→
maximum motor speed
→
0rpm cycle in a minute.
Note:
Refer to
5.6 Selecting a Regenerative Resistor
for more details on allowable regenerative energy
and frequency.
Voltage
Three-phase 400V
Servo Amplifier Model
SGDH-
05DE
10DE
15DE
20AE
30DE
SGMSH Series
App
lic
abl
e
Serv
omo
tor
Model
SGMUH-
—
10D
15D
—
30D
Capacity
(kW)
—
1.0
1.5
—
2.9
Motor
Speed
(rpm)
Rated 6000/maximum 6000
Applicable
Encoder
Standard: 17-bit incremental encoder
Continuous
Output Current
A
rms
—
2.7
4.1
—
8.1
Maximum
Output Current
A
rms
—
8.5
14
—
28
Allowable
Regenerative
Frequency
*1
(times/min)
—
27
19
—
13
Summary of Contents for SGMAH
Page 1: ...Sigma II Series Servo System User s Manual...
Page 2: ......
Page 4: ...ii This page intentionally left blank...
Page 6: ...iv This page intentionally left blank...
Page 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Page 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Page 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Page 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Page 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Page 487: ......