Sigma II User’s Manual
Chapter 7: Using the Digital Operator
7 - 18
Reference Pulse/Feedback Pulse Counter Monitor Display
The monitor display of reference pulse counter and feedback pulse counter is
expressed in 32-bit hexadecimal.
The display procedure is as follows:
Using the Hand-held Digital Operator
1.
Press the
DSPL/SET
key to select the monitor mode.
2.
Press the
Up Arrow
or
Down Arrow
key to select “Un00C” or “Un00D”.
3.
Press the
DATA/ENTER
key to display the data for the monitor number
selected in the above step.
4.
Press the
Up Arrow
or
Down Arrow
key to alternately display the
leftmost and the rightmost 16-bit data.
5.
Press both the
Up Arrow
AND
Down Arrow
keys simultaneously to clear
the 32-bit counter data.
6.
Press the
DATA/ENTER
key once more to return to the monitor number
display.
Using the Built-in Panel Operator
1.
Press the
MODE/SET
key to select the monitor mode.
2.
Press the
Up Arrow
AND
Down Arrow
keys to select “Un00C” or
“Un00D”.
3.
Press the
DATA/SHIFT
key for a minimum of one second to display the data for
the monitor number selected in the above step.
4.
Press the
Up Arrow
or
Down Arrow
key to alternately display the
leftmost 16-bit data and rightmost 16-bit data.
Leftmost 16-bit Data
Rightmost 16-bit Data
SGDM-
MODE/SET
DATA/
CHARGE
POWER
SERVOPACK
200V
YASKAWA
Leftmost 16-bit Data
Rightmost 16-bit Data
Summary of Contents for SGMAH
Page 1: ...Sigma II Series Servo System User s Manual...
Page 2: ......
Page 4: ...ii This page intentionally left blank...
Page 6: ...iv This page intentionally left blank...
Page 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Page 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Page 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Page 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Page 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Page 487: ......