I/O Signals
I/O signals are described below.
Divided encoder signals are output.
Always connect these signal terminals when a position loop is formed in the host
controller for position control.
Set a dividing ratio at the following parameter.
The dividing ratio setting is not related to the gear ratio setting (Pn202 and 203) for
the servo amplifier electronic gear function during position control.
Output Phase Form
Output PAO CN1-33
Encoder Output Phase A
Speed/Torque Control,
Position Control
Output /PAO CN1-34
Encoder Output Phase /A
Speed/Torque Control,
Position Control
Output PBO CN1-35
Encoder Output Phase B
Speed/Torque Control,
Position Control
Output /PBO CN1-36
Encoder Output Phase /B
Speed/Torque Control,
Position Control
Output PCO CN1-19
Encoder Output Phase C
Speed/Torque Control,
Position Control
Output /PCO CN1-20
Encoder Output Phase /C
Speed/Torque Control,
Position Control
PG Dividing Ratio
Pn201
Forward
rotation
Reverse
rotation
Phase A
Phase C
t
t
Phase A
Phase B
Phase B
Phase C
90°
90°
Summary of Contents for SGMAH
Page 1: ...Sigma II Series Servo System User s Manual...
Page 2: ......
Page 4: ...ii This page intentionally left blank...
Page 6: ...iv This page intentionally left blank...
Page 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Page 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Page 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Page 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Page 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Page 487: ......