Sigma II User’s Manual
Chapter 5: Parameter Settings and Functions
5 - 9
5.1.3
Limiting Torque
The SGDH servo amplifier limits torque as follows:
•
Level 1: Limits maximum output torque to protect the equipment or workpiece.
•
Level 2: Limits torque after the servomotor moves the equipment to a specified
position (internal torque limit).
•
Level 3: Always limits output torque rather than speed.
•
Level 4: Switches between speed and torque limit.
Application of levels 1 and 2 in the torque limit function are described below.
Setting Level 1: Internal Torque Limits
Maximum torque is limited to the values set in the following parameters.
Sets the maximum torque limits for forward and reverse rotation.
Used when torque must be limited due to equipment conditions.
The torque limit function always monitors torque and outputs the signals
below when the limit is reached.
The following signals are output by the torque limit function.
The torque limits are specified as a percentage of the rated torque.
Note:
If torque limit is set higher than the maximum torque of the servomotor, the maximum torque of the
servomotor is the limit.
Parameter
Signal
Setting
(%)
Control Mode
Pn402
Forward Torque Limit
Range: 0 to 800
Default Setting: 800
Speed/Torque Control,
Position Control
Pn403
Reverse Torque Limit
Range: 0 to 800
Default Setting: 800
Speed/Torque Control,
Position Control
Signal
Description
/CLT
Generated when Pn50F.0 allocates an output terminal from SO1 to SO3.
Monitor Mode (Un006)
Output signal monitor
Summary of Contents for SGMAH
Page 1: ...Sigma II Series Servo System User s Manual...
Page 2: ......
Page 4: ...ii This page intentionally left blank...
Page 6: ...iv This page intentionally left blank...
Page 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Page 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Page 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Page 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Page 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Page 487: ......