Sigma II User’s Manual
Chapter 6: Servo Adjustment
6 - 41
In speed control operation, the position loop gain is set through the host controller.
If that is not possible, adjust the position loop gain with the speed reference input
gain in Pn300 in the servo amplifier. In speed control operation, the position loop
gain set in Pn102 is enabled in zero-clamp mode only. Position loop gain K
p
is
obtainable from the following formula.
Where: K
p
(
s
-1
)
= Position Loop Gain
V
s
(
pps
)
= Constant Speed Reference
ε
(
Pulse
)
= Constant Error: The number of accumulated pulses
of the error counter at the above constant speed.
•
When the inertia ratio is larger than 10, start gain adjustments with the position and speed
loop gains slightly below the ranges given above and the speed loop integral constant
slightly over the range.
•
When the inertia ratio is much larger, start the gain adjustments with the position and
speed loop gains set to the smallest values and the speed loop integral constant to the
large value in the ranges given above.
IMPORTANT
K
p
≥
V
s
ε
Summary of Contents for SGMAH
Page 1: ...Sigma II Series Servo System User s Manual...
Page 2: ......
Page 4: ...ii This page intentionally left blank...
Page 6: ...iv This page intentionally left blank...
Page 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Page 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Page 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Page 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Page 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Page 487: ......