Sigma II User’s Manual
Chapter 9: Inspection, Maintenance, and Troubleshooting
9 - 43
9.2.5
Warning Displays
The correlation between warning displays and warning code outputs is shown in the
following table.
Warning Displays and Outputs
Warnings (Additional Warning Display) (Applicable only to SGDH
amplifiers with version # 33
or higher)
Warning
Display
Warning Code Outputs
Warning
Name
Meaning of Warning
ALO1
ALO2
ALO3
A.91
ON
OFF
OFF
Overload
This warning occurs before either of
the overload alarms (A.71 or A.72)
occurs. If the warning is ignored and
operation continues, an overload
alarm may result.
A.92
OFF
ON
OFF
Regenerative
Overload
This warning occurs before the
regenerative overload alarm (A.32)
occurs. If the warning is ignored and
operation continues, a regenerative
overload alarm may result.
Warning
Display
Warning Code Output
Warning Name
Cause
Corrective
Actions
ALO1
ALO2
ALO3
A.90
×
×
×
Excessive
position error
warning
The position errors exceed the
setting in Pn51E.
Reduce the position
errors to the value
of Pn51E or less to
restore
automatically.
Summary of Contents for SGMAH
Page 1: ...Sigma II Series Servo System User s Manual...
Page 2: ......
Page 4: ...ii This page intentionally left blank...
Page 6: ...iv This page intentionally left blank...
Page 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Page 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Page 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Page 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Page 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Page 487: ......