Sigma II User’s Manual
Chapter 7: Using the Digital Operator
7 - 50
4.
Press the
DSPL/SET
key. The display will change as shown below and offset
will be automatically adjusted.
5.
Press the
DATA/ENTER
key to return to the auxiliary function mode display.
This completes the automatic adjustment of the motor current detection offset.
Using the Built-in Panel Operator
1.
Press the
MODE/SET
key to select the auxiliary function mode.
2.
Press the
Up Arrow
or
Down Arrow
key to select the parameter Fn00E.
3.
Press the
DATA/SHIFT
key for a minimum of one second, and the display will
be as shown below.
4.
Press the
MODE/SET
key. The display will change as shown below and the
offset will be automatically adjusted.
5.
Press the
DATA/SHIFT
key for a minimum of one second to return to the
auxiliary function mode display.
This completes the automatic adjustment of the motor current detection offset.
Flashing
for one
second
SGDM-
MODE/SET
DATA/
CHARGE
POWER
SERVOPACK
200V
YASKAWA
Flashing
for one
second
Summary of Contents for SGMAH
Page 1: ...Sigma II Series Servo System User s Manual...
Page 2: ......
Page 4: ...ii This page intentionally left blank...
Page 6: ...iv This page intentionally left blank...
Page 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Page 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Page 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Page 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Page 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Page 487: ......