Sigma II User’s Manual
Chapter 7: Using the Digital Operator
7 - 7
Position Control Mode
The following tables list and explain the meanings of bit data and code displays in
Position Control Mode.
Bit Data and Meanings in Position Control Mode
Bit Datum
Meaning
Control Power ON
Lit when servo amplifier control power is ON.
Baseblock
Lit for baseblock.
Not lit when servo is ON.
Positioning Completed
Lit if error between position reference and actual motor position
is below preset value.
Preset value: Set in PN500. (Default setting is 7 pulses).
/TGON
Lit if motor speed exceeds preset value.
Preset value: Set in Pn502. (Default setting is 20rpm).
Reference Pulse Input
Lit if reference pulse is input.
Error Counter Clear Input
Lit when error counter clear signal is input.
Power Ready
Lit when main power supply circuit is operating at normal level.
Not lit when power is OFF.
Codes and Meanings in Position Control Mode
Code
Meaning
Baseblock
Servo OFF (motor power OFF)
Run
Servo ON (motor power ON)
Forward Run Prohibited
CN1-42 (P-OT) is OFF. Refer to
5.1.2 Setting the Overtravel Limit
Function.
Reverse Run Prohibited
CN1-43 (N-OT) is OFF. Refer to
5.1.2 Setting the Overtravel Limit
Function.
Alarm Status
Displays the alarm number. Refer to
9.2 Troubleshooting.
Code
Bit Data
Positioning Completed
Baseblock
Control Power ON
Reference Pulse Input
TGON
Power Ready
Error Counter Clear Input
Summary of Contents for SGMAH
Page 1: ...Sigma II Series Servo System User s Manual...
Page 2: ......
Page 4: ...ii This page intentionally left blank...
Page 6: ...iv This page intentionally left blank...
Page 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Page 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Page 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Page 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Page 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Page 487: ......