Sigma II User’s Manual
Chapter 6: Servo Adjustment
6 - 30
Procedure for Saving Results of Online Auto-Tuning
The procedure for saving the results of online auto-tuning is as follows:
Using the Hand-held Digital Operator
1.
Press the
MODE/SET
key to select Fn007 in the auxiliary function mode.
2.
Press the
DATA/ENTER
key. If the inertia ratio is 200%, for example, the fol-
lowing data will be displayed.
3.
Press the
MODE/SET
key. The following display will flash for 1 second and
then the inertia ratio will be saved.
4.
Press the
DATA/ENTER
key to return to the auxiliary function mode.
This completes the procedure for saving the results of online auto-tuning. When the
servo amplifier is turned ON again, the inertia ratio set in Pn103 will be used as the
default value.
Using the Built-in Panel Operator
1.
Press the
MODE/SET
key and select Fn007 in the auxiliary function mode.
2.
Press the
DATA/SHIFT
key for a minimum of 1 second. If the inertia ratio is
200%, for example, the following data will be displayed.
3.
Press the
MODE/SET
key. The following display will flash for 1 second and
then the inertia ratio will be saved.
4.
Press the
DATA/SHIFT
key for a minimum of 1 second to return to the auxiliary
function mode.
Flashes for
1 s.
Flashes for
1 s.
Summary of Contents for SGMAH
Page 1: ...Sigma II Series Servo System User s Manual...
Page 2: ......
Page 4: ...ii This page intentionally left blank...
Page 6: ...iv This page intentionally left blank...
Page 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Page 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Page 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Page 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Page 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Page 487: ......