Operation in Alarm Traceback Mode
The Alarm Traceback Mode can display up to ten alarms that have occurred, thus
making it possible to check what kind of alarms have been generated.
The alarm traceback data is not cleared on alarm reset or when the servo amplifier
power is turned OFF.
The data can be cleared using the special “clear alarm traceback mode.” Refer to
7.2.5 Clearing Alarm Traceback Data
for details.
Checking Alarms
Follow the procedure below to determine which alarms have been generated.
Using the Hand-held Digital Operator
1.
Press the
DSPL/SET
key to select the “Displaying alarm traceback data
(Fn000)” in the auxiliary function mode.
2.
Press the
DATA/ENTER
key, and the alarm traceback data will be displayed.
3.
Press the
Up Arrow
or
Down Arrow
key to scroll the alarm sequence
numbers up or down and display information on previous alarms.
The higher the leftmost digit (alarm sequence number), the older the alarm data.
Using the Built-in Panel Operator
1.
Press the
MODE/SET
key to select the “Displaying alarm traceback data
(Fn000)” in the auxiliary function mode.
2.
Press the
DATA/SHIFT
key for a minimum of one second to display the alarm
traceback data.
3.
Press the
Up Arrow
or
Down Arrow
key to scroll the alarm sequence
numbers up or down and display information on previous alarms.
Alarm Code
See the table of
alarms.
Alarm Sequence Number
The higher the number,
the older the alarm data.
Alarm Traceback
Display
SGDM-
MODE/SET
DATA/
CHARGE
POWER
SERVOPACK
200V
YASKAWA
Alarm Traceback
Display
Summary of Contents for SGMAH
Page 1: ...Sigma II Series Servo System User s Manual...
Page 2: ......
Page 4: ...ii This page intentionally left blank...
Page 6: ...iv This page intentionally left blank...
Page 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Page 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Page 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Page 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Page 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Page 487: ......