Sigma II User’s Manual
Chapter 5: Parameter Settings and Functions
5-106
Detailed Signal Specifications
PAO Serial Data Specifications
The number of revolutions is output in five digits.
Note: 1.
Data is “P+00000” (CR) or “P-00000” (CR) when the number of revolutions is zero.
2.
The revolution range is “+32767” to “-32768.” When this range is exceeded, the data changes
from “+32767” to “-32768” or from “-32768” to “+32767”
PSO Serial Data Specifications
The number of revolutions and the absolute position within one revolution are
always output in five and seven digits, respectively. The data output cycle is
approximately 40ms.
Data Transfer Method
Start-stop Synchronization
(ASYNC)
Baud rate
9600bps
Start bits
1 bit
Stop bits
1 bit
Parity
Even
Character code
ASCII 7-bit code
Data format
8 characters, as shown below.
Data Transfer Method
Start-stop Synchronization
(ASYNC)
Baud rate
9600bps
Start bits
1 bit
Stop bits
1 bit
Parity
Even
Character code
ASCII 7-bit code
Data format
13 characters, as shown below.
0 0 0 0 0 1 0 1 0
Data
Start bit
Even parity
1
Stop bit
“P” “+” or “-” “0” to “9” “CR”
Summary of Contents for SGMAH
Page 1: ...Sigma II Series Servo System User s Manual...
Page 2: ......
Page 4: ...ii This page intentionally left blank...
Page 6: ...iv This page intentionally left blank...
Page 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Page 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Page 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Page 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Page 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Page 487: ......