Sigma II User’s Manual
Chapter 7: Using the Digital Operator
7 - 24
Using the Built-in Panel Operator
1.
Press the
MODE/SET
key to select Fn002 in the auxiliary function mode.
2.
Press the
DATA/SHIFT
key for a minimum of one second to select the Panel
Operator Operation Mode. Operation is now possible using the panel operator.
3.
Press the
MODE/SET
key to set to the servo ON (with motor power turned
ON).
4.
Press the
Up Arrow
or
Down Arrow
key to operate the motor. The motor
keeps operating while the key is pressed.
5.
Press the
MODE/SET
key to set to the servo OFF state (with motor power
turned OFF). Alternatively, press the
DATA/SHIFT
key for a minimum of one
second to set to the servo OFF state.
6.
Press the
DATA/SHIFT
key for a minimum of one second, and the display will
revert to Fn002 in the auxiliary function mode.
This ends JOG operation under panel operator control.
The motor speed for operation under digital operator control can be changed with a
parameter:
Note:
The rotation direction of the servomotor depends on the setting of parameter Pn000.0 “Rotation
Direction.” The above example shows a case where Pn000.0 is set to “0” as a default setting.
Parameter
Signal
Setting
(rpm)
Application
Pn304
Jog Speed
Default Setting: 500
Speed Control
SGDM-
MODE/SET
DATA/
CHARGE
POWER
SERVOPACK
200V
YASKAWA
Motor Forward
Rotation
Motor Reverse
Rotation
Summary of Contents for SGMAH
Page 1: ...Sigma II Series Servo System User s Manual...
Page 2: ......
Page 4: ...ii This page intentionally left blank...
Page 6: ...iv This page intentionally left blank...
Page 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Page 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Page 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Page 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Page 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Page 487: ......