Sigma II User’s Manual
Chapter 7: Using the Digital Operator
7 - 36
Pressing the
DATA/ENTER
key after the above displays in steps 3 to 5 will also
return to the auxiliary function mode display.
This completes checking motor type procedure.
Using the Built-in Panel Operator
1.
Press the
MODE/SET
key to select the auxiliary function mode.
2.
Press the
Up Arrow
or
Down Arrow
key to select the parameter Fn011.
3.
Press the
DATA/SHIFT
key for a minimum of one second to display the
servomotor model and voltage code.
4.
Press the
MODE/SET
key to display the Servomotor capacity.
5.
Press the
MODE/SET
key, and the encoder type and resolution code will be
displayed.
Voltage
Servomotor Model
Code
Voltage
Code
Servomotor Model
00
100V
AC
or 140V
DC
00
SGMAH
01
200V
AC
or 280V
DC
01
SGMPH
02
400V
AC
or 560V
DC
02
SGMSH
03
SGMGH- A (1500rpm)
04
SGMGH- B (1000rpm)
05
SAGMDH
06
SGMUH
SGDM-
MODE/SET
DATA/
CHARGE
POWER
SERVOPACK
200V
YASKAWA
Servomotor Mode
Voltage
Capacity: Displayed value
×
10W.
In this example, the capacity is 100W.
Encoder Type
Encoder Resolution
Summary of Contents for SGMAH
Page 1: ...Sigma II Series Servo System User s Manual...
Page 2: ......
Page 4: ...ii This page intentionally left blank...
Page 6: ...iv This page intentionally left blank...
Page 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Page 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Page 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Page 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Page 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Page 487: ......