Sigma II User’s Manual
Chapter 6: Servo Adjustment
6 - 4
This function does not affect the travel distance (i.e., the number of pulses).
6.1.3
Adjusting Gain
If speed loop gain or position loop gain exceeds the allowable limit for the servo
system (including the machine to be controlled), the system will tend to vibrate or
become too sensitive. Smooth operation is not possible under such conditions.
Reduce each loop gain value to an appropriate value.
Refer to
6.2.1 Setting Servo Gain
for details regarding servo gain adjustment.
Servomotor
Servo amplifier
Acceleration/Deceleration
Reference pulses
Reference pulse
frequency
Hz
Filter applied
Pn204
Pn208
Hz
Hz
Reference pulse
frequency
Reference pulse
frequency
When using acceleration/
deceleration filter
When using average
movement filter