Sigma II User’s Manual
Chapter 3: Wiring
3 - 16
3.3.5
Wiring Main Circuit Terminal Blocks
Observe the following precautions when wiring main circuit terminal blocks.
Servo amplifiers with a capacity below 1.5kW will have connector-type terminal
blocks for main circuit terminals. Follow the procedure below when connecting to
the terminal block.
Connection Procedure
•
Strip the end of the wire, leaving the ends twisted together.
•
Open the wire insert opening of the terminal block (plug) with a tool using either
of the two procedures shown in Fig. A and Fig. B on the following page.
1. Fig. A:
Use the provided lever to open the wire insert opening .
Fig. B:
Using a commercially available 1/8in (3.0 to 3.5mm) slotted
screwdriver, press down firmly on the screwdriver insert
opening to release the wire insert slot.
2. Figs A and B
: Insert the wire end into the opening and then clamp it
tightly by releasing either the lever or the screwdriver.
• Remove the terminal block from the servo amplifier prior to wiring.
• Insert only one wire per terminal on the terminal block.
• Make sure that the core wire is not electrically shorted to adjacent core wires.
• Reconnect any wires that were accidentally pulled out.
CAUTION
0.31 to 0.35in (8 to 9mm)
Fig. A
Fig. B
Summary of Contents for SGMAH
Page 1: ...Sigma II Series Servo System User s Manual...
Page 2: ......
Page 4: ...ii This page intentionally left blank...
Page 6: ...iv This page intentionally left blank...
Page 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Page 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Page 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Page 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Page 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Page 487: ......