4-
198
Operation
4
12. “SYSTEM” mode
n
NOTE
• This parameter is supported by
controllers of Ver. 8.63 onwards. On
earlier version controllers, the area
check output turns on when the robot
is within a specified area, and turns
off when outside it.
• Any point on the boundary of the
specified area is determined to be
within the area.
• If the area check cannot be
performed correctly due to return-to-
origin incomplete, operation other
than “MANUAL” or “AUTO” mode,
or a memory error, then the area
check output will turn off regardless
of the criterion setting.If the
specified port is the same as the port
used by the program, then the area
check output has priority.
• The default setting is “IN” (output is
on within specified area).
5. Condition for area check output
Selects the condition that allows the area check output to turn on, from either when
the robot is within a specified area or when outside it.
[Procedure]
1) Select “5. Condition” in “SYSTEM>OPTION>POS.OUT>SELECT” mode.
2) Press the
F 1
(EDIT) key.
Fig. 4-12-72 Criterion selection for area check output
SYSTEM
>OPTION>POS.OUT>SELECT
1.Output of area1
3.Compare Point number11
P1
4.Compare Point number12
P2
MAIN
IN
OUT
2.Output port1(DO & SO)
20
5.Condition
IN
V8.63
3) Select the criterion for area check output with the
F 1
(IN) or
F 2
(OUT) key.
Setting
IN
OUT
Meaning
Turns on when the robot enters a specified area.
Turns on when the robot goes out of a specified area.
4) Press the
ESC
key to quit the setting. To continue selecting other items, use the
cursor (
↑
/
↓
) keys.
Summary of Contents for RCX142
Page 1: ...User s Manual ENGLISH E YAMAHA 4 AXIS ROBOT CONTROLLER E92 Ver 1 09 RCX142 ...
Page 2: ......
Page 18: ...MEMO ...
Page 24: ...1 6 MEMO ...
Page 26: ...MEMO ...
Page 36: ...MEMO ...
Page 300: ...4 238 MEMO ...
Page 302: ...MEMO ...
Page 336: ...MEMO ...
Page 360: ...6 24 MEMO ...
Page 362: ...MEMO ...
Page 374: ...MEMO ...
Page 384: ...8 10 MEMO ...
Page 386: ...MEMO ...
Page 394: ...MEMO ...