10-
45
10
T
roubleshooting
1. Error Messages
21.11 : System error (EmgHalt)
Code
: &H150B
Meaning/Cause
: Software error occurred.
Action
: Contact our company with details of this problem.
21.12 : System error (RTOS)
Code
: &H150C
Meaning/Cause
: Software error occurred.
Action
: Contact our company with details of this problem.
21.13 : System error (CRFPOS)
Code
: &H150D
Meaning/Cause
: 1. Current position of driver does not match the instructed position.
Action
: 1. Replace the driver.
2. Replace the controller.
21.14 : DPRAM error (PTP data)
Code
: &H150E
Meaning/Cause
: 1. Failed to write PTP command data into driver.
Action
: 1. Replace the driver.
2. Replace the controller.
21.41 : System error (EXCEPTION)
Code
: &H1529
Meaning/Cause
: a. Software error occurred.
Action
: 1. Contact our company with details of this problem.
[22] Major hardware errors
22.1 : AC power low
Code
: &H1601
Meaning/Cause
: a. AC supply voltage dropped below 85% of rated voltage.
b. Power source has insufficient capacity.
Action
: 1. Check the AC supply voltage
2. Check if supply voltage drops during robot operation.
3. Lower the robot duty cycle.
Dedicated output
: *1
Caution
: This error always occurs when the power is cut off
Summary of Contents for RCX142
Page 1: ...User s Manual ENGLISH E YAMAHA 4 AXIS ROBOT CONTROLLER E92 Ver 1 09 RCX142 ...
Page 2: ......
Page 18: ...MEMO ...
Page 24: ...1 6 MEMO ...
Page 26: ...MEMO ...
Page 36: ...MEMO ...
Page 300: ...4 238 MEMO ...
Page 302: ...MEMO ...
Page 336: ...MEMO ...
Page 360: ...6 24 MEMO ...
Page 362: ...MEMO ...
Page 374: ...MEMO ...
Page 384: ...8 10 MEMO ...
Page 386: ...MEMO ...
Page 394: ...MEMO ...