4-
209
4
Operation
12. “SYSTEM” mode
12.3.4.2 Setting the double-carrier parameters
[Procedure]
1) Press the
F 4
(W.CARRIER) in "SYSTEM>OPTION" mode.
Fig. 4-12-86 Double-carrier parameter setting (1)
SYSTEM
>OPTION>W.CARRIER
V8.58
1.Stroke[mm]
0.00
2.Carrier1
M1
3.Carrier2
M2
4.Control mode
OFF
EDIT
JUMP
Valid keys and submenu descriptions in this mode are shown below.
F1
F2
Cursor key
(
↑
/
↓
)
Valid keys
EDIT
JUMP
Menu
Function
Edits the parameter being selected with the cursor.
Jumps to the specified point number.
Moves the cursor up and down.
1. Stroke setting
[Procedure]
1) Select "1. Stroke [mm]" and press
F 1
(EDIT).
Fig. 4-12-87 Double-carrier parameter setting (2)
SYSTEM
>OPTION>W.CARRIER>EDIT
V8.58
1.Stroke[mm]
0.00
2.Carrier1
M1
3.Carrier2
M2
4.Control mode
OFF
[1- ] Enter >650.00
n
NOTE
The stroke corresponds to the current
position of one carrier that was moved
from its origin position, to a point
closest to the other carrier remaining
at its origin position after return-to-
origin.