4-
203
4
Operation
12. “SYSTEM” mode
3. Operating device in “SERVICE” mode
Specify the operating device to use.
ALL
MPB/COM
MPB/DI
MPB
Description
Only MPB operation is allowed.
Allows MPB and dedicated input.
Allows MPB and online commands.
Allows operation by all devices.
[Procedure]
1) Select “3. Operating device” in “SYSTEM>OPTION>SERVICE” mode.
2) Press the
F 1
(EDIT) key.
Fig. 4-12-77 Editing the "SERVICE" mode devices
SYSTEM
>OPTION>SERVICE
V8.35
1.Service level
2.Movement Vel
3.Operating device
MPB
MPB/DI
MPB/COM
ALL
LEVEL 3
<3%
MPB
3) Select the operating device with the
F 1
(MPB) to
F 4
(ALL) keys.
4) Press the
ESC
key to quit the setting. To continue selecting other items, use the
cursor (
↑
/
↓
) keys.
n
NOTE
The settings made here are only valid
until the controller power is turned
off. Save these settings if you want to
use them again after power is turned
off.
w
WARNING
Settings may be changed but the
customer must bear
responsibility for them. The
customer should keep safety in
mind when making changes.