12.5.3
Displaying the total operation time
Use the following procedure to check the total controller operation time.
[Procedure]
1) Press the
F 5
(TOTAL) key.
Fig. 4-12-101 Displaying the total operation time
SYSTEM
>DIAGNOS>TOTAL
V8.35
Total operation time (04/07/20, 12:05)
YEAR DAY HOUR MIN
Power-on time = 0/ 14/ 10: 34
Run time = 0/ 2/ 8: 45
CLEAR
The 3rd line shows the date and time that the total operation time was reset.
The "Power-on time" is the total time that the controller power has been on.
The "Run time" is the total time that the controller has performed automatic
operation.
Pressing the
F 5
(CLEAR) key resets the total operation time. The display
shows the new total operation time starting from the date and time after reset.
2) Press the
ESC
key to return to "SYSTEM>DIAGNOS" mode.
12.5.4
System error details display
Details of important software errors that have occurred in the past can be displayed.
[Procedure]
1) Press the
F 15
(SYS. CHK) key.
Fig. 4-12-102 Error details
SYSTEM
>DIAGNOS>SYS.CHK
V8.35
Exception error Information
Type = -16 (04/07/30,13:42:38)
ErCode= 000000E0
Inf1 = 841081E6
Inf2 = 40000030
"No system error code" will appear if no error has occurred.
2) Press the
ESC
key to return to the "SYSTEM>DIAGNOS" mode.
Summary of Contents for RCX142
Page 1: ...User s Manual ENGLISH E YAMAHA 4 AXIS ROBOT CONTROLLER E92 Ver 1 09 RCX142 ...
Page 2: ......
Page 18: ...MEMO ...
Page 24: ...1 6 MEMO ...
Page 26: ...MEMO ...
Page 36: ...MEMO ...
Page 300: ...4 238 MEMO ...
Page 302: ...MEMO ...
Page 336: ...MEMO ...
Page 360: ...6 24 MEMO ...
Page 362: ...MEMO ...
Page 374: ...MEMO ...
Page 384: ...8 10 MEMO ...
Page 386: ...MEMO ...
Page 394: ...MEMO ...