3-
11
3
Installation
7. I/O connections
The various input/output (I/O) signals from peripheral equipment can be connected to the robot con-
troller. Each I/O is set with a number, and the I/O connector to be used depends on that number.
For more detailed information on inputs and outputs, see Chapter 6, "Parallel I/O interface" or see
Chapter 7, "SAFETY I/O interface".
The following describes terms used in the manual.
a. NPN specifications
NPN specifications indicate that a DO (digital output) type NPN open-collector
transistor is used for the I/O port having a transistor and photocoupler, and a
corresponding DI (digital input) is also used. NPN specifications therefore make use
of a sink output and a source input (see drawing below).
Current
Current
DO output (sink type)
DI input (source type)
N.COM
P.COM
NPN
b. PNP specifications
PNP specifications indicate that a DO (digital output) type PNP open-collector transistor
is used for the I/O port having a transistor and photocoupler, and a corresponding DI
(digital input) is also used. PNP specifications therefore make use of a source output
and a sink input (see drawing below).
DO output (source type)
DI input (sink type)
Current
Current
N.COM
P.COM
PNP
Summary of Contents for RCX142
Page 1: ...User s Manual ENGLISH E YAMAHA 4 AXIS ROBOT CONTROLLER E92 Ver 1 09 RCX142 ...
Page 2: ......
Page 18: ...MEMO ...
Page 24: ...1 6 MEMO ...
Page 26: ...MEMO ...
Page 36: ...MEMO ...
Page 300: ...4 238 MEMO ...
Page 302: ...MEMO ...
Page 336: ...MEMO ...
Page 360: ...6 24 MEMO ...
Page 362: ...MEMO ...
Page 374: ...MEMO ...
Page 384: ...8 10 MEMO ...
Page 386: ...MEMO ...
Page 394: ...MEMO ...