Weld Schedules
4 - 22
Modified: 9/17/08
MedWeld 4000 Operator’s Guide
M-032116 Programs #T03300, #T02300 and #T02400
41
SET VALVE n TOUCH DOWN RESSURE TO mm PSI
(n = 1,2; m = 0–99)
This function sets a reduced “touch down” pressure for the weld
gun to approach and initially touch the work pieces, prior to
clamping them and applying the final pressure before welding. This
prevents the weld gun from closing too fast and hard on the work
pieces.
n
sets the cylinder number: Either #1 or #2. Set the pressure
mm
in
the range 0 – 99 PSI.
42
SET VALVE n TIP DRESS RESSURE (PSI)
(n = 1,2; m = 0–99)
This function sets a pressure for the specified weld gun that can be
different from the welding or “touch down” pressure settings. This
is used when running tip dress schedules.
n
sets the cylinder number: Either #1 or #2. Set the pressure
mm
in
the range 0 – 99 PSI.