Weld Schedules
4 - 44
Modified: 9/17/08
MedWeld 4000 Operator’s Guide
M-032116 Programs #T03300, #T02300 and #T02400
FUN47
*
FUN48
*
FUN49
WELD NNN IMP. NNNN0 AMP HI NNNN0 AMP
FUN50
TURN ON WELD COMPLETE
FUN51
TURN OFF WELD COMPLETE
FUN52
TURN ON ISOLATION CONTACTOR
FUN53
TURN OFF ISOLATION CONTACTOR
FUN54
TURN ON VALVE #N
FUN55
TURN OFF VALVE #N
FUN56
TURN ON PRESSURE SELECT
FUN57
TURN OFF PRESSURE SELECT
FUN58
TURN ON WELD IN PROGRESS
FUN59
TURN OFF WELD IN PROGRESS
FUN60
IMPULSE NN HEAT HALF CY NN COOL HALF
FUN61
ABORT IF NO INITIATE FOR NN CYCLES
FUN62
REPEAT (AT NEXT FUNCTION)
FUN63
TURN ON OUTPUT #N
FUN64
TURN OFF OUTPUT #N
FUN65
WAIT NNN CY INP #N TO BE (0=OFF,1=ON)
FUN66
WAIT FOR INPUT #N TO BE (0=OFF,1=ON)
FUN67
EXTEND WHILE INPUT #N IS (0=OFF,1=ON)
FUN68
WAIT NNN CY FOR PRESSURE SWITCH INPUT
FUN69
WAIT FOR PRESSURE SWITCH INPUT
FUN70
WAIT NNN CY FOR WELD PROCEED INPUT
FUN71
WAIT FOR WELD PROCEED INPUT
FUN72
OUTPUT #1 ON DELAY
FUN73
OUTPUT #1 OFF DELAY
FUN74
WELD NNN IMP. NN %I HIGH NN %I LOW
FUN75
EXTEND UNTIL NO INITIATE
FUN76
SEC. CURR LIMITS: HI=NNNN0 LOW=NNNN0
FUN77
ISOLATION CONTACTOR DELAY = NN SECONDS
FUN78
PROCESS WELD FAULTS
FUN79
WAIT NNN CYCLES FOR SYSTEM COOLING
FUN80
*
FUN81
*
FUN82
LINEAR STEPPER #N ASSIGNED (0 = OFF)
FUN83
*
FUN84
WINDOW: HI=+NN'% LO=-NN'%
FUN85
WAIT FOR NO INITIATE IF FAULT
FUN86
TIP DRESS ADVANCE: GROUP NN
FUN87
SET SPC OFFSET TO NN
FUN88
SEND ALL SAMPLES UNTIL NEXT SPC OFFSET
FUN89
VERIFY CYLINDER #1 IS OUT OF RETRACT
FUN90
TRANSFORMER TURNS RATIO NNN:1
FUN91
*
FUN92
*
FUN93
*
FUN94
EXTEND WELD IF LOW CURRENT LIMIT FAULT
FUN95
EXTEND WELD IF CURRENT LESS THAN NNNN AMPS
FUN96
*
FUN97
C-FACTOR LIMIT: HI=NNNN LO=NNNN
FUN98
*
FUN99
GOTO SEQ#NN