Setup Parameters
MedWeld 4000 Operator’s Guide
Modified: 9/17/08
5 - 29
M-032116 Programs #T03300, #T02300 and #T02400
HEAT CYCLE LIMIT (0=SEAM)
(60 CYCLES)
ISOLATION CONTACTOR DELAY
(5 SEC)
HIGH CURRENT LIMIT WINDOW
(20%)
LOW CURRENT LIMIT WINDOW
(20%)
SHORTED SCR CYCLE LIMIT
(60 CYCLES)
DATA COLLECTION SAMPLE SIZE
(5)
DATA COLLECTION SAMPLE FREQUENCY (100)
MAXIMUM TIP DRESSES
(50)
TIPS DOWN VERIFIED CURRENT
(10 AMPS)
TRANSFORMER TURNS RATIO
(100:1)
NOMINAL LINE VOLTAGE
(468 VOLTS)
NOMINAL C FACTOR
(999)