MedWeld 4000 Overview
1 - 14
Modified: 12/16/08
MedWeld 4000 Operator’s Guide
M-032116 Programs #T03300, #T02300 and #T02400
Configuring the
FieldBus Daughter
Board
LEDs indicate operating status of the FieldBus daughter board, and
status of its connection to the network. Refer to the following tables.
Module Status LEDs
Network Status LEDs
After installation and before beginning operation, DIP switches on the
communications daughter board must be correctly set. Refer to the next
section and the following tables for more information.
NOTE:
The DIP switch settings apply when configuring both the DeviceNet
and Profibus systems, and for both rocker and slider switches:
Bit
State
Function
–
OFF
Device not powered.
LED1
Green
Device is operational.
Flashing Green
Configuration is missing or incorrect: Device
requires commissioning.
LED2
Red
Unrecoverable fault.
Flashing Red
Minor (recoverable) fault.
Bit
State
Function
–
OFF
Device not powered / not on-line.
LED3
Green
Link is OK; On-line; Connected.
Blinks Green
On-line but not connected.
LED4
Red
Critical link failure.
Blinks Red
Connection timeout.
LED3/4
Blinks Green /
Red
A specific communication faulted device. The device
has detected a Network Access error and is in the
Communication Faulted state. The device subse-
quently received and accepted an identity Communi-
cation Faulted Request - Long Protocol message.
TXD
LED
Blinks red during
configuration/
communications.
The control is either communicating to the optional
daughter board serial port, or FieldBus configuration
is occurring.
RXD
LED
Blinks green dur-
ing configuration/
communications.
The control is receiving data from the optional
daughter board serial port, or FieldBus configuration
is occurring.
• ON (closed) sets the bit to a
0
.
• OFF (open) sets the bit to a
1
.
Rocker:
Slider:
ON
ON