MedWeld 4000 Overview
MedWeld 4000 Operator’s Guide
Modified: 12/16/08
1 - 15
M-032116 Programs #T03300, #T02300 and #T02400
Configuration Switches
You can configure the baud rate and node address for the module via
DIP switch SW1. Configure as follows:
•
Node Address:
Use the 6 least significant switches to set the node
address. Valid range of settings is
0 - 63
for DeviceNet,
0 - 126
for
Profibus. Set Switch
6 > 1
.
•
Baud Rate:
Set the baud rate using the two most significant
switches, 8 and 7. The valid settings are
•
00
= 125 kb/sec
•
01
= 250 kb/sec
•
10
= 500 kb/sec
Refer to this diagram for proper
switch orientation.
Switches (Fieldbus Specific Input Register)
Node Address:
Set the node address for the MedWeld 4000, in the
range
0 - 126
. A 7-pole binary switch specifies the address. Refer to the
following table:
ON
8 7 6 5 4 3 2 1
MAC ID
(MSB - LSB)
Baud rate
(MSB - LSB)
}
}
Switch #7
#6
#5
#4
#3
#2
#1
Node Address
Bit 6 (MSB)
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0 (LSB)
0
0
0
0
0
0
0
0
0
0
1
0
0
0
1
1
0
0
0
0
0
1
0
2
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
0
1
1
1
1
0
1
61
0
1
1
1
1
1
0
62
0
1
1
1
1
1
1
63
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
1
1
1
1
1
0
0
124
1
1
1
1
1
0
1
125
1
1
1
1
1
1
0
126