Weld Schedules
4 - 26
Modified: 9/17/08
MedWeld 4000 Operator’s Guide
M-032116 Programs #T03300, #T02300 and #T02400
Default Weld Schedules in Program #T03300
Following are the default sequences for program #T03300. Separate
sequences apply to operation for a robot, welding machine and manual
or portable welding gun. Schedules 1 - 15 are defined for each default
sequence. Schedules 16 - 99 are defined as blank.
Default Weld
Sequence: Robot
START OF SEQUENCE
82
LINEAR STEPPER #01 ASSIGNED (0 = OFF)
76
SEC. CURR LIMITS: HI=00250 LO=99990
90
TRANSFORMER TURNS RATIO: 100:1
63
TURN ON VALVE #1
52
TURN ON ISOLATION CONTACTOR
01
SQUEEZE 30 CYCLES
30
WELD 10 CY. 00050 AMPS
78
PROCESS WELD FAULTS
03
HOLD 05 CYCLES
85
WAIT FOR NO INITIATE IF FAULT
55
TURN OFF VALVE #1
53
TURN OFF ISOLATION CONTACTOR
END OF SEQUENCE
Default Weld
Sequence: Machine
START OF SEQUENCE
82
LINEAR STEPPER #00 ASSIGNED (0 = OFF)
76
SEC. CURR LIMITS: HI=00000 LO=99990
90
TRANSFORMER TURNS RATIO: 100:1
63
TURN ON OUTPUT #0
52
TURN ON ISOLATION CONTACTOR
01
SQUEEZE 30 CYCLES
30
WELD 10 CY. 00050 AMPS
78
PROCESS WELD FAULTS
03
HOLD 05 CYCLES
50
TURN ON WELD COMPLETE
64
TURN OFF OUTPUT #0
75
EXTEND UNTIL NO INITIATE
51
TURN OFF WELD COMPLETE
53
TURN OFF ISOLATION CONTACTOR
END OF SEQUENCE
Default Weld
Sequence: Gun
START OF SEQUENCE
82
LINEAR STEPPER #01 ASSIGNED (0 = OFF)
76
SEC. CURRENT LIMITS: HI=00000 LO= 99990
90
TRANSFORMER TURNS RATIO 100:1
54
TURN ON VALVE #1
05
INITIAL SQUEEZE 25 CYCLES
62
REPEAT (AT NEXT FUNCTION)
54
TURN ON VALVE #1
01
SQUEEZE 30 CYCLES
30
WELD 10 CY. 00050 AMPS
78
PROCESS WELD FAULTS
03
HOLD 05 CYCLES
55
TURN OFF VALVE #1
04
OFF 20 CYCLES
END OF SEQUENCE