Weld Schedules
4 - 30
Modified: 9/17/08
MedWeld 4000 Operator’s Guide
M-032116 Programs #T03300, #T02300 and #T02400
Default Weld
Schedule: Gun
START OF SCHEDULE
82
LINEAR STEPPER #01 ASSIGNED (0 = OFF)
76
SEC. CURR LIMITS: HI=00000 LOW= 99990
90
TRANSFORMER TURNS RATIO 073:1
54
TURN ON VALVE #1
05
INITIAL SQUEEZE 25 CYCLES
62
REPEAT (AT NEXT FUNCTION)
54
TURN ON VALVE #1
52
TURN ON ISOLATION CONTACTOR
01
SQUEEZE 30 CYCLES
30
WELD 10 CY. 00050 AMPS
78
PROCESS WELD FAULTS
03
HOLD 05 CYCLES
55
TURN OFF VALVE #1
53
TURN OFF ISOLATION CONTACTOR
04
OFF 20 CYCLES
END OF SCHEDULE