Advanced Software Features
7 - 16
Modified: 9/17/08
MedWeld 4000 Operator’s Guide
M-032116 Programs #T03300, #T02300 and #T02400
PARTIAL RETRACT #n DELAY (CY/2) (See page 5-11.)
This is the length of time to allow for the gun to move from the
fully-retracted position to the partial retract position, as shown
below:
Cautions:
This timer will determine the partial retract opening.
The size of the opening
increases
as you reduce the
length of time; it
decreases
as you increase the length
of time. If the control does not start from the full open
position each time, the partial retract opening may vary
in size.
A heavy gun will have difficulty maintaining a constant
partial retract position as the gun’s orientation changes.
(The heavier the gun, the more difficulty in maintaining
a constant opening size in vertical versus horizontal
orientations.)
BLOCKING VALVE #n DELAY (CY/2) (See page 5-11.)
This parameter sets the length of time to allow for the gun to move
from the fully-closed position to the partial retract position, as
shown below:
Partial Retract Delay Timer:
Full retract
Partial retract
Blocking Valve Delay Timer:
Partial retract
Fully closed