Weld Schedules
MedWeld 4000 Operator’s Guide
Modified: 9/17/08
4 - 37
M-032116 Programs #T03300, #T02300 and #T02400
Function List T03302 (AC w/Ohma Cylinder Support)
FUN01
SQUEEZE NN CYCLES
FUN02
COOL NN CYCLES
FUN03
HOLD NN CYCLES
FUN04
OFF NN CYCLES
FUN05
INITIAL SQUEEZE NN CYCLES
FUN06
*
FUN07
WAIT NN CYCLES
FUN08
*
FUN09
STEPPER MACH=NN PART=NN (0=OFF)
FUN10
RESET STEPPER NN
FUN11
*
FUN12
*
FUN13
*
FUN14
*
FUN15
TURN ON ADVANCE VALVE #N SQZ NN CY
FUN16
TURN ON INTENSIFY VALVE SQZ NN CY
FUN17
TURN OFF INTENSIFY/ADV VALVE #N
FUN18
TURN OFF INT/ADV VALVE #N OPEN NNN CY/2
FUN19
*
FUN20
WELD NN CYC/IMP AT NN %I
FUN21
TEMPER NN CYC/IMP AT NN %I
FUN22
PREHEAT NN CYC/IMP AT NN %I
FUN23
POSTHEAT NN CYC/IMP AT NN %I
FUN24
PRE-WELD NN CYC/IMP AT NN %I
FUN25
WELD NN CYCLES AT NN.N%I
FUN26
WELD NN HALF-CYCLES AT NN.N%I
FUN27
*
FUN28
*
FUN29
*
FUN30
WELD NN CYC/IMP AT NNNN0 AMPS
FUN31
TEMPER NN CYC/IMP AT NNNN0 AMPS
FUN32
PREHEAT NN CYC/IMP AT NNNN0 AMPS
FUN33
POSTHEAT NN CYC/IMP AT NNNN0 AMPS
FUN34
PRE-WELD NN CYC/IMP AT NNNN0 AMPS
FUN35
*
FUN36
WELD NN HALF CYCLES NNNN0 AMPS
FUN37
*
FUN38
WELD NNN IMP NNNN0 AMPS HIGH NNNN0 AMPS LOW
FUN39
TEST FIRE NN %I
FUN40
SLOPE NN %I TO NN %I
FUN41
SET VALVE N TOUCH DOWN PRESSURE NN PSI
FUN42
SET VALVE N TIP DRESS PRESSURE NN PSI
FUN43
SET VALVE N CYLINDER PRESSURE TO NN PSI
FUN44
*
FUN45
SLOPE NNNN0 AMPS TO NNNN0 AMPS
FUN46
*
FUN47
WAIT ,2, CYCLES FOR PRESSURE ACHIEVED*
FUN48
TURN ON CONTACTOR SELECT #,2,$,1,MAXSCRS
FUN49
TURN OFF CONTACTOR SELECT #,2,$,1,MAXSCRS
FUN50
TURN ON WELD COMPLETE*
FUN51
TURN OFF WELD COMPLETE*
FUN52
TURN ON ISOLATION CONTACTOR*
FUN53
TURN OFF ISOLATION CONTACTOR*
FUN54
TURN ON VALVE #,1,$,0,MAXOUTS
FUN55
TURN OFF VALVE #,1,$,0,MAXOUTS
FUN56
TURN ON PRESSURE SELECT #,1,$,0,PSELOUTM