To set the Discrete I/O options, press the
1
key while in the
IO Mapping
screen shown above. This screen now appears:
Follow these steps:
1. Use the
W
or
E
keys as needed to scroll to the
RELOAD DIO
DEFAULTS:
option.
>?D5*
If resetting the defaults, cycle power to the control
OFF
, then back
ON
,
before programming any additional changes.
2. Press
U
to reload from one of the supplied Discrete I/O defaults.
Selecting
OFF
performs no action. Selecting
Default 1
reloads
from the supplied Default 1. Selecting
Default 2
reloads from the
supplied Default 2.
3. Press
E
to scroll down to the
ISOLATION CONTACTOR:
option.
4. If your control has the optional isolation contactor, use
O
or
U
as needed to set this option
ENABLED
for programming.
5. If no isolation contactor is included, set the option
DISABLED
.
6. To accept these settings for downloading, press
. A message,
DOWNLOAD COMPLETE -- RESTART TIMER
, appears
momentarily.
>?D5*
If the
Normal/Program
jumper is not in the proper position, the DEP will
indicate
. . .
and reset the options to what is currently programmed in the
control.
7. To exit this screen and return to the
IO Mapping
screen, press
.
>?D5*
For the changes you entered to take effect, you must reset the weld
processor to
RUN
mode. You may make all programming changes
before cycling power to the control.
8. Turn OFF power to the control.