Fault Conditions
8 - 22
Modified: 9/17/08
MedWeld 4000 Operator’s Guide
M-032116 Proograms #T03300, #T02300 and #T02400
DRIVER
Fault
DEP-100S displays
HARD OVERCUR-
RENT fault.
Shorted weld transformer
primary.
Replace weld transformer.
Shorted weld transformer
primary cable.
Replace cable.
Open weld transformer
primary cable.
Replace cable.
Missing mains line phase.
Replace blown fuse in bus plug.
Shorted inverter transistor.
Replace inverter.
Transistor driver failure.
Replace inverter.
Failure of inverter snubber
circuit.
Replace inverter.
Bridge rectifier diode/
SCR failure.
Replace inverter.
DEP-100S displays
LOW VOLTAGE
fault.
Inverter processor failure.
Replace inverter.
LED On
Inverter
Symptom
Probable Cause
Corrective Action