background image

*25073*

25073

© Allegion 2016

Printed in U.S.A.

25073 Rev. 06/16-j

The LCN Sentronic HSA (

H

older 

S

canner 

A

ctivated) is a door closer with a scanner activated hold open feature designed to hold the door 

open as long as there is traffic passing through the opening.

Door Closer With Scanner Activated Hold Open

4311 HSA

Installation Instructions

Scanner

Cover

Power Board

Mounting Bracket For

Surface Run Conduit

Hole For Concealed

Conduit

End Cap

Track

Roller

Arm

Track

Plugs (4)

Arm Shaft Screw

Arm Shaft Spacer

Cover Screw

Spring

Power

Adjustment

Packing

Nut

How To Tell Hand Of Door:

=

58 N-m

33 Ft/lbs

Maximum

Opening

Torque

LH

RH

=

58 N-m

33 Ft/lbs

Maximum

Opening

Torque

Scanner

Cover

Power Board

Mounting Bracket For

Surface Run Conduit

Hole For Concealed

Conduit

End Cap

Track

Roller

Arm

Track

Plugs (4)

Arm Shaft Screw

Arm Shaft Spacer

Cover Screw

Spring

Power

Adjustment

Packing

Nut

How To Tell Hand Of Door:

=

58 N-m

33 Ft/lbs

Maximum

Opening

Torque

LH

RH

=

58 N-m

33 Ft/lbs

Maximum

Opening

Torque

Customer Service

1-877-671-7011

www.allegion.com/us

Summary of Contents for LCN 4311 HSA

Page 1: ...led Conduit End Cap Track Roller Arm Track Plugs 4 Arm Shaft Screw Arm Shaft Spacer Cover Screw Spring Power Adjustment Packing Nut How To Tell Hand Of Door 58 N m 33 Ft lbs Maximum Opening Torque LH RH 58 N m 33 Ft lbs Maximum Opening Torque Scanner Cover Power Board Mounting Bracket For Surface Run Conduit Hole For Concealed Conduit End Cap Track Roller Arm Track Plugs 4 Arm Shaft Screw Arm Shaf...

Page 2: ...ce arm on closer shaft and secure with arm shaft screw 1g Remove end cap from track and insert track roller Reinsert end cap into end of track and insert track plugs Using fasteners provided mount track to door per template on page 6 1h Loosen set screw in end of arm open door approx 30 pull ar m over top of door and connect to track roller Tighten set screw firmly 1i Spring Power Adjustment See F...

Page 3: ...t Black Wires To Input Voltage Leads Polarity Not Important Connect Green Wire To Earth Ground Connect Black Wires To Input Voltage Leads Polarity Not Important Figure 1 Spring Power Adjustment Closing Speed Regulation Backcheck Main Speed Latch Speed 1 2 3 Spring Adjustment Increase Force Decrease Force Figure 2 Figure 3 Concealed Wiring Optional Surface Run Wiring Connect Green Wire To Earth Gro...

Page 4: ... release and close 2e Continuous hold open Press switch once to put unit in continuous hold open mode Press the switch again to activate the timed hold open mode Door must be opened beyond 80 for hold open function to take effect 3 Electrical Data 4311 HSA SCANNER ACTIVATED HOLD OPEN Voltage 24V AC DC Nominal 10 15 Standby Current 0 010A Hold Open Current 0 120A Figure 4 To Adjust Scanner Sensitiv...

Page 5: ...4311 HSA ...

Reviews: