SECTION 5 – INSTALLATION ANd prOgrAmmINg
PAGE 5-4 REV. 0 2014-MAY-02
Bracket mounting Instructions (Continued)
NOTICE
Only hand-tighten enclosure nut, do not use
mechanical force such as a wrench.
FIgUrE 5-7
ENCLOSUrE NUT
009310
7. If required, feed cables through opening in bracket base.
Reinstall the Swivel Mount to the base according to the
position determined in Step 1. Carefully align joint teeth
and secure with the swivel joint screws to lock swivel
mount in place. Do not over tighten, 20-25 in-lbs
(2.26-2.82 N•m) maximum. See Figure 5-8.
FIgUrE 5-8
mOUNTINg BrACKET WITH
CHECKFIrE 210 dISpLAY mOdULE
009311
mOUNTINg INTErFACE CONTrOL mOdULE (ICm)
Mount on a flat surface that will properly support the ICM
during all vehicle/equipment operating and environmental
conditions (e.g. shock and vibration).
1. Refer to layout drawing for planned location. Verify the
location meets approval of the vehicle/equipment owner
and/or vehicle/equipment service manager.
2. Confirm access to the ICM for proper cable connections,
periodic inspections, and maintenance. Verify module loca-
tion and connections will not interfere with vehicle/equip-
ment operation, service, and maintenance.
3. Using the ICM mounting plate as a template (see Figure
5-9), mark and drill 9/32 in. (7 mm) holes in the flat surface
(4 places).
4. Secure ICM to mounting surface using appropriate length
fasteners (1/4 in. (6 mm) screws or bolts with lock washers
and nuts).
FIgUrE 5-9
SUrFACE mOUNTINg
009273 / 009312
CHECKFIRE 210
Detection and Actuation System
RUBBER
wASHER
ENCLOSURE
NUT
PULL CABLES
THROUGH CENTER
OPENING
9/32 IN.
(2.8 mm) DIA.
4 1/4 IN.
(108 mm)
3 1/2 IN.
(89 mm)
7 5/8 IN.
(194 mm)
3/8 IN.
(905 mm)