e-STUDIO2020C/2330C/2820C/2830C/3520C/3530C/4520C
© 2008 - 2011 TOSHIBA TEC CORPORATION All rights reserved
FIRMWARE UPDATING
8 - 8
(4)
Press the [ON/OFF] button while simultaneously holding down the [4] and [9] buttons.
Data in the USB media are checked and the checking status is displayed on the screen.
The screen for selecting items to be updated is displayed after approx. 3 minutes.
On this screen, the current firmware version of this equipment and the firmware version of data to
be updated are displayed.
Fig. 8-3
Notes:
•
The display of items on this screen varies depending on the types of data written on the USB
media. Each item is displayed only when each data file is written on the USB media in the
following conditions.
•
If the USB media are not recognized properly, “Set Correct USB Storage Device” message is
displayed. In this case, disconnect the USB media and connect again within 3 minutes, or
shut down the equipment and connect the device properly. Then repeat the procedure from
(4).
•
If any of the error messages below is displayed, confirm if the update program or the data file
in the USB media is correct. Then repeat the procedure from (4).
Item
Condition
1. OS Update
firmImage0.bin is written.
2. HDD SYS Update
hdd.bin is written.
3. Engine Main Firmware Update
T450MWW.xxx is written.
*
xxx is version.
4. Scanner Firmware Update
T450SLGWW.xxx is written.
*
xxx is version.
5. MEP Firmware Update
For the details, see the following page:
P.8-17 "8.1.2 Imaging Acceleration Board ROM
Error
number
Error message
Cause
-
There is no mentusb2.o
Update program loader (mentusb2.o)
is not stored.
01
There is no dlFirmWare_2820C_3530C in the
storage device.
Model specific update program
(dlFirmWare_2820C_3530C ) is not
stored.
02
Error Loadmodule
Module loading failed.
03
Machine Model Get Error
Model information was not
downloaded.
04
Please Change USB Storage or Please Check
ROMDATA
Checking of data file failed.
05
Other models ROMDATA Vxxxx.xxx x
*
The version name comes at “xxxx.xxx.x”.
Master data of other model (hdd.bin)
are stored.