e-STUDIO2020C/2330C/2820C/2830C/3520C/3530C/4520C
© 2008 - 2011 TOSHIBA TEC CORPORATION All rights reserved
ADJUSTMENT
3 - 2
3.1.2
Adjustment of the Auto-Toner Sensor
When the developer material is replaced, adjust the auto-toner sensor in the following procedure.
(1)
Install the cleaner and developer unit.
Note:
Do not install the toner cartridge.
(2)
While pressing [0] and [5] simultaneously, turn the power ON. The following message will be
displayed.
Fig. 3-2
(3)
Key in a code and press the [START] button.
Fig. 3-3
(4)
The message below will be displayed approx. 2 minutes later and the adjustment starts:
•
During the adjustment, “Current sensor voltage (V)” shown in (B) automatically changes and
gradually approaches to “Target value (V) for adjustment reference voltage” shown in (A).
Fig. 3-4
Code
200: All developer materials
201: Developer material Y
202: Developer material M
203: Developer material C
204: Developer material K
206: Developer material YMC
100%
A
A3
TEST MODE
[0] [5]
[POWER]
100%
200
A3
TEST MODE
(Code)
[START]
(B)
(C)
(A)
M: z.zzV C: z.zzV K: z.zzV
Y: z.zzV
M: x.xxV C: x.xxV K: x.xxV
Y: x.xxV
M:
C:
K:
ww%
Y:
(B): Current sensor voltage (V)
(A): Target value (V) for adjustment reference voltage
(C): Adjustment value, Humidity (%)