ADJUSTMENT
3 - 27
Adjustments and Checks using Test Chart No. TCC-1
Following items can be checked with the Test Chart No. TCC-1.
1. Points to be measured in the chart
Fig. 3-20
<Adjustment order>
[0] [5] [Power ON]
→
(Chart TCC-1)
→
[FAX]
→
[START] (A3/LD, 100%, Full color and Text/
Photo)
A: 05-405
→
200±0.5 mm (0.1 mm/step)
B: 05-306
→
5±0.5 mm (0.04 mm/step)
C: 05-340
→
150±0.5 mm (0.02 mm/step)
D: 05-305
→
10±0.5 mm (0.08 mm/step)
C
D
B
A