6
© 2008 - 2011 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2020C/2330C/2820C/2830C/3520C/3530C/4520C
ERROR CODE AND TROUBLESHOOTING
6 - 115
[2D12] Message reception error
[2D13] Message transmission error
Turn the power OFF and then back ON. Perform the job in error again.
[2D14] [2D61] Invalid parameter
When a template is used, form the template again.
If the error still occurs, turn the power OFF and then back ON, and perform the job again.
[2D15] Exceeding the maximum size for file sharing
Divide the file in error into several files and retry. Or retry the job in a single-page format.
[2D20] System management module access abnormality
[2D21] Job control module access abnormality
[2D22] Job control module access abnormality
[2D60] File library access abnormality
Turn the power OFF and then back ON. Perform the job in error again.
Check if there are no other running jobs and perform the HDD formatting (08-690).
If the recovery is still not completed, replace the SYS board.
[2D30] Directory creation failure
[2D31] File creation failure
[2D33] File access failure
Check if the access privilege to the storage directory is writable.
Check if the server disc, local disk or USB storage device has a sufficient space in capacity.
[2D40] Image conversion abnormality
Turn the power OFF and then back ON. Perform the job in error again.
Replace the main memory and perform the job again.
If the error still occurs, first, check if there are no jobs existing and then initialize the shared folder
using the Setting Mode (08-667).
When the Imaging Acceleration Board (GE-1170, optional) is installed
Refer to the following page:
Service Manual "26.4.4 Abnormality Related to Imaging Acceleration Board (GE-1170, optional)"
[2D43] Encryption error
Turn the power OFF and then back ON. Perform the job in error again.
[2D44] Encryption PDF enforced mode error
Reset the encryption and perform the job in error again.
If an image file not encrypted is created, consult your administrators.
[2D62] File server connection error
Check the IP address or path of the server.
Check if the server is operating properly.