2
© 2008 - 2011 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2020C/2330C/2820C/2830C/3520C/3530C/4520C
SELF-DIAGNOSTIC MODE
2 - 13
126
Image position aligning sensor (front/
rear) LED ON
176
Code No.126 function OFF
1
Code
Function
Procedure
201
1st drawer feed clutch ON/OFF
3
202
2nd drawer feed clutch ON/OFF
3
204
Bypass feed clutch ON/OFF
3
206
LCF pickup solenoid ON/OFF
3
207
LCF end fence reciprocating movement
2
208
LCF end fence motor ON/OFF
3
209
LCF feed clutch ON/OFF
3
210
LCF transport clutch ON/OFF
3
218
Key copy counter count up
2
222
ADU clutch ON/OFF
3
225
PFP transport clutch ON/OFF
3
226
PFP upper drawer feed clutch ON/OFF
3
228
PFP lower drawer feed clutch ON/OFF
3
229
Middle roller (upper) transport speed drive clutch ON/OFF
3
230
Middle roller (lower) transport speed drive clutch ON/OFF
3
231
Middle roller (upper) process speed drive clutch ON/OFF
3
232
Bridge unit gate solenoid ON/OFF
3
233
Middle roller (lower) process speed drive clutch ON/OFF
3
234
Bypass pickup solenoid ON/OFF
3
235
Discharge LED (K) ON/OFF (Do not let it radiate to the photoconductive drum for a long
time.)
3
236
Discharge LED (Y/M/C) ON/OFF (Do not let it radiate to the photoconductive drum for a
long time.)
3
239
Switching contact/release of 2nd transfer roller
2
240
Drum switching motor (switches position in the black/color mode)
2
241
1st transfer roller cam motor (switches contact/release of transfer belt)
2
242
1st drawer tray-up motor ON (tray up)
2
243
2nd drawer tray-up motor ON (tray up)
2
248
Developer bias (K) [DC] ON/OFF (Operational without process unit K)
3
249
Developer bias (K) [AC] ON/OFF (Operational without process unit K)
3
252
Main charger (K) ON/OFF (Operational without process unit K)
3
253
Main charger (Y/M/C) ON/OFF (Operational without process unit Y/M/C)
3
254
Developer bias (Y) [DC] ON/OFF (Operational without process unit Y)
3
255
Developer bias (M) [DC] ON/OFF (Operational without process unit M)
3
256
Developer bias (C) [DC] ON/OFF (Operational without process unit C)
3
257
Developer bias (Y/M/C) [AC] ON/OFF (Operational without process unit Y/M/C)
3
261
Scan motor ON (Automatically stops at limit position)
2
264
Scanner fan motor (high speed) ON/OFF
3
265
Scanner fan motor (low speed) ON/OFF
3
267
Scanner exposure lamp ON/OFF
3
271
LCF tray-up motor UP/DOWN
2
278
PFP upper drawer tray-up motor ON (tray up)
2
Code
Function
Code
Function
Procedure