70
used for all measurement functions, math operations, trigger operations and reading
hold.
How to use the reading memory
User can store the readings and access to the stored readings through either the front
panel operation or the remote interface operation.
※
Note: Each datum stored from DL-2060 to remote interface will be in a first in and first
out condition.
Front Panel Operation
Before using the reading memory feature, user needs to select a measurement function
(or the math function) first and then select the trigger mode.
To store readings, use the following steps:
Press STORE button, and the multimeter will start to store the readings produced until
the specified number of readings is reached. The default number of readings to store is
100. To change this number, press CONFIG and then STORE buttons. Then use
◁
and
▷
buttons to move between the digits and
▽
and
△
buttons to increase or decrease
numbers as desired. When ready, press ENTER button.
The default number of readings
will be restored when the meter has been turned off.
The location of the buttons are
shown with red rectangle frames in
Figure 4-28
.
※
Note: The MEM annunciator will be lit while the multimeter stores readings and be
turned off when the specified number of readings is reached.
Procedures: STORE
→
<NUMBER>
Figure 4-28
To recall the stored readings, use the following steps:
Press RECALL button, and the multimeter will display all the stored readings starting
from the first reading. Use
◁
and
▷
or
▽
and
△
buttons to move from the first
reading to the last reading the meter has stored.
The locations of the buttons are shown
with red rectangle frames in
Figure 4-29
.