General Signal Viewing > Spectrum
Spectrum Display
Item
Display element
Description
1
Vert Offset
Sets the top of graph value. This is only a visual control for panning the graph.
The Reference Level is adjusted in the Toolbar and the Ampl control panel.
By default, Vert Offset = Ref Level.
2
dB/div
Sets the vertical scale value. The maximum value is 20.00 dB/division.
3
RBW
Sets the resolution bandwidth. Note that when the RBW is set to Auto, its
value is italicized.
4
VBW
Enables the VBW (Video Bandwidth)
fi
lter. See Setup > Settings >
.
5
Autoscale
Adjusts the Vertical and Horizontal scaling to display the entire trace on
screen.
6
Position
Default function is CF - center frequency (equivalent to the Freq setting).
If Horizontal scaling has been manually adjusted in Settings > Scale, then
Offset will replace CF as the setting at the bottom-left corner of the screen.
7
Span / Scale
Default function is Span - frequency difference between the left edge of
the display and the right edge. If Horizontal scaling has been manually
adjusted in Settings > Scale, then Scale will replace Span as the setting at
the bottom-right corner of the screen.
8
Clear
Restarts multi-trace functions (Avg, Hold).
9
Function
Readout of the Detection and Function selections for the selected trace.
10
Show
Controls whether the selected Trace is visible or not. When trace is Off, the
box is not checked.
11
Trace
Selects a trace. Touching here pops up a context menu listing the available
traces, whether they are enabled or not. If user selects a trace that is not
currently enabled, it will be made enabled.
xxx
Touchscreen Actions on Markers in the Graph Area
Action
Description
Mouse click within 1/2 div. of
a marker
Selects the marker and updates the marker display to show the selected marker’s values.
Touch marker to select and
then use knob, or arrow keys
Adjust the setting associated with the Marker.
Touch and drag a marker
Changes marker position to the "drop point".
xxx
Changing the Spectrum Display Settings (see page 80)
RSA6100A Series Real-Time Spectrum Analyzers Help
79