![Tektronix RSA6100A Series Help Manual Download Page 129](http://html1.mh-extra.com/html/tektronix/rsa6100a-series/rsa6100a-series_help-manual_1078169129.webp)
Analog Modulation > FM
FM Display
Item
Element
Description
1
Check mark indicator
The check mark indicator in the upper, left-hand corner of the display shows
when the FM display is the optimized display.
2
Top of Graph control
Sets the frequency indicated at the top of the graph. Since the Position value
at the vertical center of this graph remains constant as the Top of Graph value
is adjusted, the Vertical Scale increases as the Top of Graph value increases,
which also affects the bottom of graph readout. Vertical Scale can also be
controlled from the Settings control panel’s Scale tab.
3
Position
Speci
fi
es the frequency shown at the center of the graph display. Changing
this value moves the trace up and down in the graph, which affects the Top of
Graph and Bottom of Graph values as well.
4
Bottom of Graph Readout
Displays the frequency value at the bottom of the graph.
5
Measurement readouts
Displays numeric values for the +Pk (positive frequency deviation), –Pk
(negative frequency deviation), RMS (RMS value of the deviation), Pk-Pk
(peak-to-peak frequency deviation), and Pk-Pk/2 (peak-to-peak frequency
deviation divided by two).
6
Position
Speci
fi
es the horizontal position of the trace on the graph display.
7
Scale
Adjusts the time range of the graph. By decreasing the scale (full-scale time
over 10 divisions), the graph essentially becomes a window that you can
move over the acquisition record by adjusting the horizontal position.
8
Clear
Clears the trace and numeric measurement results.
9
Trace Detection readout
Displays the Settings > Trace > Detection setting.
10
Freq Error
This readout can show Freq Error or Freq Offset. When it displays Freq
Error, it shows the difference between the instrument Frequency setting and
the measured value of the signal’s carrier frequency. When it displays Freq
Offset, it shows the frequency offset speci
fi
ed on the Settings > Parameters
tab. If Freq Error is displayed, it also indicates that the Carrier frequency
detection setting is Auto. If Freq Offset is displayed, it indicates that the
Carrier frequency detection setting is manual.
xxx
Changing the FM Settings (see page 118)
RSA6100A Series Real-Time Spectrum Analyzers Help
117
Summary of Contents for RSA6100A Series
Page 2: ......
Page 12: ...Table of Contents viii RSA6100A Series Real Time Spectrum Analyzers Help...
Page 28: ...Orientation Elements of the Display 16 RSA6100A Series Real Time Spectrum Analyzers Help...
Page 307: ...Search Limits Testing Define Tab Search RSA6100A Series Real Time Spectrum Analyzers Help 295...