Reference > Troubleshooting
Error and Information Messages
ict. Increase Span or Analysis Length
The measurement is not running because the actual RBW used by the measurement is too large for the
current acquisition span. Typically, the analysis length is too short as well.
Either increase the span or increase the Analysis Length.
The current span or acquisition bandwidth is too small to allow a wider RBW
fi
lter.
Increase the span or acquisition bandwidth if the decreased RBW is not acceptable.
The current Spectrum Length (or Analysis Length if Spectrum Length is not Independent) is too small
to allow the requested RBW.
Increase the Spectrum Length (or Analysis Length) if the increased RBW is not acceptable.
RBW limited by AcqBW to: XX Hz
The requested RBW is too close to the acquisition BW. Increase the frequency range of the measurement
(for example, Span).
RBW too small/large for current Acq BW
If the RBW is set manually, it is possible for the acquisition bandwidth to be incompatible with the
RBW setting.
Change the RBW setting.
Adjust the Acq BW setting, either directly (Setup > Acquire > Sampling Params: select on of the
manual modes) or by adjusting the measurement bandwidth of the selected display (Setup > Acquire >
Sampling Params: All Auto).
Recall error: Setup not completely restored
An error occurred while recalling a Setup
fi
le. Thus, the current setup may be a combination of settings
from the Setup
fi
le and the previous Setup.
Recall the setup again.
An error occurred while recalling a Setup, Trace or Data
fi
le. This can occur because of a problem opening
the
fi
le (operating system error) or because of a problem with the contents of the
fi
le.
Recall the
fi
le again.
This is a status message displayed while data is being restored from a
fi
le.
This input signal power is outside the range of the analog-to-digital converter circuitry.
Decrease the input signal power or increase the internal attenuation setting.
372
RSA6100A Series Real-Time Spectrum Analyzers Help
Summary of Contents for RSA6100A Series
Page 2: ......
Page 12: ...Table of Contents viii RSA6100A Series Real Time Spectrum Analyzers Help...
Page 28: ...Orientation Elements of the Display 16 RSA6100A Series Real Time Spectrum Analyzers Help...
Page 307: ...Search Limits Testing Define Tab Search RSA6100A Series Real Time Spectrum Analyzers Help 295...