Control by console
Installer Manual -
TP8-64 BUS
6-12
6.4
ACTIVATION/DEACTIVATION REMOTE
CONTROLS
The master programming menu permits the manual activation and deactivation of the
remote controls.
Enter the master code (default 12345)
+
12345
master code (default)
+
yw
to select the remote controls menu
+
yw
to select the remote controls to activate/deactivate
Commands available
+
#
to activate the remote control
+
*
to deactivate the remote control
+
EXIT
to confirm and quit
QUICK ACTIVATION/DEACTIVATION (IF ENABLED)
If the quick menu of the consoles is enabled, the manual activation and deactivation of
the remote controls without code is possible.
+
yw
to select the remote controls to activate/deactivate
+
#
to activate the remote control
+
*
to deactivate the remote control
+
EXIT
to confirm and quit
6.5
MANUAL COMMUNICATOR BLOCK
During an alarm call, it is possible to block the communicator, i.e. interrupt the active
alarm call cycle and thos waiting to be executed.
Enter the Master code (or a user code) enabled for the manual communicator block,
and press
EXIT
, e.g.:
+
12345
EXIT
On the display is viewed
Abort Telephone ? * NO # YES.
Commands available
+
#
to block the communicator
+
*
to abandon and quit
Menu
1
Remote ctrl
Remote ctrl
1
Remote ctrl 01
Rem. ctrl 01
1
Activation
[ # ]
Abort telephone ?
* NO
# YES
WARNING
The block of the telephone calls is only permitted with master code or one of the standard user
codes (1 to 62).
The blocking command stops all the active alarm calls cycles as well as those waiting.
The block of the telephone calls is not permitted in case of hold-up alarm. In this case, the cycle
continues uninterrupted.
Summary of Contents for TP8-64 BUS
Page 4: ...IV Installer Manual TP8 64 BUS...
Page 12: ...Index Installer Manual TP8 64 BUS 8...
Page 16: ...Generalfeatures Installer Manual TP8 64 BUS 1 4...
Page 32: ...Hardware Installer Manual TP8 64 BUS 2 16...
Page 48: ...Input expansion modules Installer Manual TP8 64 BUS 2A 16...
Page 54: ...Output expansion modules Installer Manual TP8 64 BUS 2B 6...
Page 58: ...Console Installer Manual TP8 64 BUS 2C 4...
Page 64: ...Keypoints Installer Manual TP8 64 BUS 2D 6...
Page 70: ...Programming interfaces Installer Manual TP8 64 BUS 2E 6...
Page 72: ...Telephone communicator with GSM module Installer Manual TP8 64 BUS 2F 2...
Page 82: ...Wireless expansion modules Installer Manual TP8 64 BUS 2G 10...
Page 88: ...Set up Installer Manual TP8 64 BUS 3 6...
Page 138: ...Programming by PC Installer Manual TP8 64 BUS 4 44...
Page 176: ...Programming by console Installer Manual TP8 64 BUS 5 38...
Page 180: ...Control by console Installer Manual TP8 64 BUS 6 4 OPERATIONS WITHOUT CODE...
Page 192: ...Control by console Installer Manual TP8 64 BUS 6 16...
Page 222: ...Technicalspecifications Installer Manual TP8 64 BUS 8 16...
Page 224: ...Appendix A Protocols Installer Manual TP8 64 BUS A 2...
Page 228: ...Appendix B Special procedures Installer Manual TP8 64 BUS B 2...
Page 240: ...Appendix B Special procedures Installer Manual TP8 64 BUS B 14...
Page 242: ...Appendix C Code management Installer Manual TP8 64 BUS C 2...
Page 245: ...TP8 64 BUS Installer Manual Code management Appendix C C 5...
Page 246: ...Appendix C Code management Installer Manual TP8 64 BUS C 6 TP8 64 BUS INSTALLER MANUAL...