TP8-64 BUS
- Installer Manual
Control by console
6-5
6.1
ARMING
The control panel can be armed through the programs (1 to 8) in one of the following
ways:
z
with master code or standard user code enabled for the program in question
z
with quick arming command
z
with contact connected to a key zone
z
automatically by timer
The programs group the zones (1 to 64) to be activated, i.e. enabled for the detection
of alarms, simultaneously upon arming of the program. The programs can be armed
one at a time (single arming) or simultaneously (multiple arming).
The LCD console permits arming/disarming and by-pass of maximum 15 programs. In
addition, it permits arming with exclusion of the open zones.
Common zones (if multiple arming is enabled only)
If a zone is included in several programs and is defined common zone, it is enabled
for the detection of alarms only when all the programs it is included in are armed.
Example: if a system is used by two appartments that share the same entrance zone,
the owners of the appartments can arm the proper part of the system independently
through the program/s associated to it and with the proper user codes. The common
zone (entrance), however, is activated only if the programs of both appartments it is
included in are armed simultaneously.
CHECK SYSTEM STATUS
Prior to arming of the control panel, when the control panel is in stand-by, always
check the status of the zones (detectors) pressing # (hash):
+
#
YES
On the display are viewed the zones that result open in sequence with an interval of
approx. 2 seconds between one another. After scanning of the zones the control
panel returns to stand-by.
CHECK PROGRAM LED STATUS
The yellow LED indicate the status of the programs:
z
LED on
= program armed
z
LED off
= program in stand-by
z
LED blinking quickly
(2 flashes per second)
= exit time, arming phase or warning of end of by-pass
z
LED blinking slowly
(1 flash per second)
= program partset or not OK during arming phase
The red LED indicate the program alarms:
z
LED on
= alarm memory
z
LED off
= program OK (no program alarm active)
z
LED blinking quickly
(2 flashes per second)
= prealarm or tamper active
z
LED blinking slowly
(1 flash per second)
= program alarm active
Tue
19 JUN 07
Work. 10 : 45
OPEN ZONES
None
OPEN ZONES
Zone 2
WARNING
The alarm is released as soon as 32 keys have been pressed without entering a valid code.
In case of false code alarm, the buzzers of all the consoles connected are activated for 30 seconds
and the console that has released the alarm is inhibited for 2 minutes.
To stop the alarm, enter a valid code (master or standard user code) on any of the other consoles.
WARNING
On arming of the program in presence of open zones, the alarm devices programmed (sirens/logic
outputs/telephone channels) are activated unless the open zones are excluded with a procedure
explained lateron.
Summary of Contents for TP8-64 BUS
Page 4: ...IV Installer Manual TP8 64 BUS...
Page 12: ...Index Installer Manual TP8 64 BUS 8...
Page 16: ...Generalfeatures Installer Manual TP8 64 BUS 1 4...
Page 32: ...Hardware Installer Manual TP8 64 BUS 2 16...
Page 48: ...Input expansion modules Installer Manual TP8 64 BUS 2A 16...
Page 54: ...Output expansion modules Installer Manual TP8 64 BUS 2B 6...
Page 58: ...Console Installer Manual TP8 64 BUS 2C 4...
Page 64: ...Keypoints Installer Manual TP8 64 BUS 2D 6...
Page 70: ...Programming interfaces Installer Manual TP8 64 BUS 2E 6...
Page 72: ...Telephone communicator with GSM module Installer Manual TP8 64 BUS 2F 2...
Page 82: ...Wireless expansion modules Installer Manual TP8 64 BUS 2G 10...
Page 88: ...Set up Installer Manual TP8 64 BUS 3 6...
Page 138: ...Programming by PC Installer Manual TP8 64 BUS 4 44...
Page 176: ...Programming by console Installer Manual TP8 64 BUS 5 38...
Page 180: ...Control by console Installer Manual TP8 64 BUS 6 4 OPERATIONS WITHOUT CODE...
Page 192: ...Control by console Installer Manual TP8 64 BUS 6 16...
Page 222: ...Technicalspecifications Installer Manual TP8 64 BUS 8 16...
Page 224: ...Appendix A Protocols Installer Manual TP8 64 BUS A 2...
Page 228: ...Appendix B Special procedures Installer Manual TP8 64 BUS B 2...
Page 240: ...Appendix B Special procedures Installer Manual TP8 64 BUS B 14...
Page 242: ...Appendix C Code management Installer Manual TP8 64 BUS C 2...
Page 245: ...TP8 64 BUS Installer Manual Code management Appendix C C 5...
Page 246: ...Appendix C Code management Installer Manual TP8 64 BUS C 6 TP8 64 BUS INSTALLER MANUAL...