Control by console
6-7
WARNING
The zones definded as NOT EXCLUDIBLE are not listed. If a zone is already excluded it does not
appear in the list either.
Once you have excluded all the zones you wanted to exclude, it is possible to confirm
the exclusion and procede with arming without awaiting expiry of the zone exclusion
time by pressing:
+
EXIT
to confirm the exclusion and abort the zone exclusion time
If all the zones are excluded, the process is stopped automatically.
IMMEDIATE CONFIRMATION OF ARMING
The zone exclusion time stops approximately after 10 seconds from the exclusion of
the last zone.
It is possible to abort the wait and obtain immediate arming by pressing:
+
#
The zones remain excluded until disarming of the program. They are activated
automatically again the next time the program is armed.
6.1.1.3 TOTAL ARMING
After entering the master code and during the 10 seconds destinated for the selection
of the programs, it is possible to obtain total arming, i.e. arming of all the programs by
pressing:
+
#
YES
to arm all the programs
The control panel initiates the zone exclusion time.
The corresponding yellow program LED start blinking.
6.1.2 ARMING WITH STANDARD USER CODE
Whereas the master code is always enabled for all the programs, the user codes
control merely those programs they have been enabled for by the installer or the
holder of the master code.
Enter the user code appropriately programmed, e.g. standard user code number 1:
+
11111
For the 10 seconds to come, it is possible to select the programs to be armed/
disarmed (pressing the program number once the program is selected, pressing it
again the program is deselected).
On every keystroke the counter is reset.
Select the programs to be armed, e.g.:
+
12
Procede as for arming with master code (see § 6.1.1).
6.1.2.1 TOTAL ARMING
See § 6.1.1.3
6.1.3 QUICK ARMING (IF ENABLED)
It is possible to speed up the arming process by pressing the key * (star) followed by
the program number, e.g.:
+
*1
+
*2
Repeat the command for all the programs to be armed.
WARNING
The programs that are already armed are not influenced.
To abort arming of the programs selected press the
EXIT
key. The process is aborted and the
control panel returns to stand-by.
- ACCESS -
Master
- ACCESS -
User 001
WARNING
Quick arming is only permitted through the consoles that have been programmed appropriately by
the installer.
It is not permitted in case of trouble/general alarm or fault (low battery, power failure etc.). At the
attempt at doing so, on the display is viewed
! ARM. DENIED !
followed by the kind of alarm.
Summary of Contents for TP8-64 BUS
Page 4: ...IV Installer Manual TP8 64 BUS...
Page 12: ...Index Installer Manual TP8 64 BUS 8...
Page 16: ...Generalfeatures Installer Manual TP8 64 BUS 1 4...
Page 32: ...Hardware Installer Manual TP8 64 BUS 2 16...
Page 48: ...Input expansion modules Installer Manual TP8 64 BUS 2A 16...
Page 54: ...Output expansion modules Installer Manual TP8 64 BUS 2B 6...
Page 58: ...Console Installer Manual TP8 64 BUS 2C 4...
Page 64: ...Keypoints Installer Manual TP8 64 BUS 2D 6...
Page 70: ...Programming interfaces Installer Manual TP8 64 BUS 2E 6...
Page 72: ...Telephone communicator with GSM module Installer Manual TP8 64 BUS 2F 2...
Page 82: ...Wireless expansion modules Installer Manual TP8 64 BUS 2G 10...
Page 88: ...Set up Installer Manual TP8 64 BUS 3 6...
Page 138: ...Programming by PC Installer Manual TP8 64 BUS 4 44...
Page 176: ...Programming by console Installer Manual TP8 64 BUS 5 38...
Page 180: ...Control by console Installer Manual TP8 64 BUS 6 4 OPERATIONS WITHOUT CODE...
Page 192: ...Control by console Installer Manual TP8 64 BUS 6 16...
Page 222: ...Technicalspecifications Installer Manual TP8 64 BUS 8 16...
Page 224: ...Appendix A Protocols Installer Manual TP8 64 BUS A 2...
Page 228: ...Appendix B Special procedures Installer Manual TP8 64 BUS B 2...
Page 240: ...Appendix B Special procedures Installer Manual TP8 64 BUS B 14...
Page 242: ...Appendix C Code management Installer Manual TP8 64 BUS C 2...
Page 245: ...TP8 64 BUS Installer Manual Code management Appendix C C 5...
Page 246: ...Appendix C Code management Installer Manual TP8 64 BUS C 6 TP8 64 BUS INSTALLER MANUAL...