![Tecnoalarm TP8-64 BUS Installer Manual Download Page 99](http://html1.mh-extra.com/html/tecnoalarm/tp8-64-bus/tp8-64-bus_installer-manual_1071792099.webp)
TP8-64 BUS
- Installer Manual
Programming by PC
4-5
DETECTOR
Permits association and configuration of the detector or contact by clicking on the correspondent item:
Technology
Determines the kind of detector or contact:
z
Dual technology
z
Contact
z
Barrier
z
Microwave
z
Inertia
z
24H
z
PIR
z
Pulse count
z
RDV
Type
Permits the selection of the modell of the device.
Filter
Determines the response time or sensitivity according to the kind of the detector or contact selected.
PROGRAMMING OF A DEVICE CONNECTED VIA ZONE BUS
Type
Select the type from the devices listed (WINBEAM/S from 2 to 5 beams - DOORBEAM/S from 6 to 8 beams).
Beams
Permits enabling/disabling of determined beams (the flag indicates that the beam has been enabled).
Position cable
Permits the selection of the cable position (top/bottom).
Response time
Permits programming of the response time (T) of the device at two levels (0.2 seconds or 0.5 seconds).
Functioning mode
Permits the definition of the modality of alarm detection:
z
1 for 1 sec. or 2 adj. for T
The alarm is released if any beam is interrupted for 1 second or two adjacent beams for the response time (T)
programmed.
z
2 adj. for T
The alarm is released if two adjacent beams are interrupted for the response time (T) programmed.
z
3 adj. for T lower part or 2 adj. for T
The alarm is released if three adjacent beams in the lower part of the barrier or two adjacent beams are
interrupted for the response time programmed.
z
1 for T
The alarm is released if any beam is interrupted for the response time programmed.
Power
Permits programming of the beam power at four levels (off, low, medium, high).
Repeat the procedure for every zone to be configured (max. 64), then press:
z
OK
to confirm and quit
z
Abandon
to quit without saving
Summary of Contents for TP8-64 BUS
Page 4: ...IV Installer Manual TP8 64 BUS...
Page 12: ...Index Installer Manual TP8 64 BUS 8...
Page 16: ...Generalfeatures Installer Manual TP8 64 BUS 1 4...
Page 32: ...Hardware Installer Manual TP8 64 BUS 2 16...
Page 48: ...Input expansion modules Installer Manual TP8 64 BUS 2A 16...
Page 54: ...Output expansion modules Installer Manual TP8 64 BUS 2B 6...
Page 58: ...Console Installer Manual TP8 64 BUS 2C 4...
Page 64: ...Keypoints Installer Manual TP8 64 BUS 2D 6...
Page 70: ...Programming interfaces Installer Manual TP8 64 BUS 2E 6...
Page 72: ...Telephone communicator with GSM module Installer Manual TP8 64 BUS 2F 2...
Page 82: ...Wireless expansion modules Installer Manual TP8 64 BUS 2G 10...
Page 88: ...Set up Installer Manual TP8 64 BUS 3 6...
Page 138: ...Programming by PC Installer Manual TP8 64 BUS 4 44...
Page 176: ...Programming by console Installer Manual TP8 64 BUS 5 38...
Page 180: ...Control by console Installer Manual TP8 64 BUS 6 4 OPERATIONS WITHOUT CODE...
Page 192: ...Control by console Installer Manual TP8 64 BUS 6 16...
Page 222: ...Technicalspecifications Installer Manual TP8 64 BUS 8 16...
Page 224: ...Appendix A Protocols Installer Manual TP8 64 BUS A 2...
Page 228: ...Appendix B Special procedures Installer Manual TP8 64 BUS B 2...
Page 240: ...Appendix B Special procedures Installer Manual TP8 64 BUS B 14...
Page 242: ...Appendix C Code management Installer Manual TP8 64 BUS C 2...
Page 245: ...TP8 64 BUS Installer Manual Code management Appendix C C 5...
Page 246: ...Appendix C Code management Installer Manual TP8 64 BUS C 6 TP8 64 BUS INSTALLER MANUAL...