Control by console
Installer Manual -
TP8-64 BUS
6-8
6.1.4 ARMING THROUGH KEY ZONE
The control panel can be armed through a contact connected to a zone programmed
by the installer as key zone.
Every time the contact is opened, all the programs that contain the key zone are
armed.
EXIT TIME
The zones defined as delayed upon arming observe an exit time programmed by the
installer. If the programs selected contain delayed zones, these are only armed on
expiry of the exit time. Once the exit time has expired, the yellow program LED are lit
and remain lit until disarming of these programs. If the programs selected do not
contain delayed zones, the programs in question are armed immediately.
6.1.5 AUTOMATIC ARMING
The control panel can be armed automatically using the 16 timers. Therefore, it is
possible to schedule arming with a determined frequency and at a determined time
acting on determined programs.
WARNING OF AUTOMATIC ARMING
At the time and for the period of time programmed by the installer on the display is
viewed a warning of imminent automatic arming and blink the yellow program LED on
the console.
According to programming, the buzzers of the consoles are activated, too.
EXIT TIME
The zones defined as delayed upon arming observe an exit time programmed by the
installer. If the programs selected contain delayed zones, these are only armed on
expiry of the exit time.
Once the exit time has expired, the yellow program LED become lit and remain lit until
disarming of these programs. If the programs selected do not contain delayed zones,
the programs in question are armed immediately on disappearance of warning of
automatic arming.
ABORT OF AUTOMATIC ARMING
Automatic arming can be aborted in the following way:
z
Enter the master code
z
Select the timer menu
z
Select the timer to be blocked
6.1.6 ARMING DURING THE ACCESS PERIODS
It is possible to define up to 8 access periods of the codes. As a consequence, the
codes are enabled for arming and disarming during the access periods associated by
the installer or the holder of the master code only.
WARNING
Arming through key zone is direct, i.e. the exclusion of zones is
not
possible.
It is not permitted in case of trouble/general alarm or fault (low battery, power failure etc.). At the
attempt at doing so, on the display is viewed
! ARM. DENIED !
followed by the kind of alarm.
Arming
automatic
WARNING
Automatic arming can only be aborted by the holder of the master code.
WARNING
Automatic arming is direct, i.e. the exclusion of zones is
not
possible.
It is always executed even in presence of trouble/general alarm or fault (low battery, power failure
etc.).
WARNING
Outside the access periods associated the codes are not accepted by the control panel and any
attempt at acceding to the system will have no effect. When trying to do so, on the display is viewed
ACCESS ! DENIED !
.
Summary of Contents for TP8-64 BUS
Page 4: ...IV Installer Manual TP8 64 BUS...
Page 12: ...Index Installer Manual TP8 64 BUS 8...
Page 16: ...Generalfeatures Installer Manual TP8 64 BUS 1 4...
Page 32: ...Hardware Installer Manual TP8 64 BUS 2 16...
Page 48: ...Input expansion modules Installer Manual TP8 64 BUS 2A 16...
Page 54: ...Output expansion modules Installer Manual TP8 64 BUS 2B 6...
Page 58: ...Console Installer Manual TP8 64 BUS 2C 4...
Page 64: ...Keypoints Installer Manual TP8 64 BUS 2D 6...
Page 70: ...Programming interfaces Installer Manual TP8 64 BUS 2E 6...
Page 72: ...Telephone communicator with GSM module Installer Manual TP8 64 BUS 2F 2...
Page 82: ...Wireless expansion modules Installer Manual TP8 64 BUS 2G 10...
Page 88: ...Set up Installer Manual TP8 64 BUS 3 6...
Page 138: ...Programming by PC Installer Manual TP8 64 BUS 4 44...
Page 176: ...Programming by console Installer Manual TP8 64 BUS 5 38...
Page 180: ...Control by console Installer Manual TP8 64 BUS 6 4 OPERATIONS WITHOUT CODE...
Page 192: ...Control by console Installer Manual TP8 64 BUS 6 16...
Page 222: ...Technicalspecifications Installer Manual TP8 64 BUS 8 16...
Page 224: ...Appendix A Protocols Installer Manual TP8 64 BUS A 2...
Page 228: ...Appendix B Special procedures Installer Manual TP8 64 BUS B 2...
Page 240: ...Appendix B Special procedures Installer Manual TP8 64 BUS B 14...
Page 242: ...Appendix C Code management Installer Manual TP8 64 BUS C 2...
Page 245: ...TP8 64 BUS Installer Manual Code management Appendix C C 5...
Page 246: ...Appendix C Code management Installer Manual TP8 64 BUS C 6 TP8 64 BUS INSTALLER MANUAL...