KIP ANSWERING MACHINE
The control panel may be connected toghether with other
devices such as answering machines to the same telephone
line, which answer incoming calls with higher priority. In this
case, it is possible to program the skip answering machine
function. The skip answering machine function is enabled by
programming 17 rings. Set the priority of the answering
machine at more than 3 to 5 rings.
When call the control panel, procede as follows:
-
Dial the number and replace the receiver after the first ring
-
Call again after 6 but no later than 60 seconds from the first
call.
If the control panel receives the second call within 6 to 60
seconds from the first one, interrupted after the first ring, it
answers immediately.
SELECTION OF THE FUNCTION
+
yw
to select the function
+
#
YES
to confirm the selection
Commands available
+
#
YES
to enable the function
+
*
NO
to disable the function
+
0
...
9
to enter the value
+
EXIT
to accept programming and quit the submenu
5.14.2
PABX NUMBER
If the control panel is connected to a telephone line after a private automatic branch
exchange (PABX) switchboard, to capture the line it is necessary to dial a PABX
number of 1 to 16 digits.
Commands available
+
yw
to delete an existing number
+
#*
to insert the DTMF symbols #(hash) and *(star)
+
0
...
9
to enter the value
+
EXIT
to accept programming and quit the submenu
5.14.3
CONFIGURATION OF THE CHANNELS
The incorporated telephone section provides 8 independent channels (A...H) that are
individually programmable for the transmission of the events to private persons as
well as monitoring stations.
Every channel can be programmed with a description, a principal and a reserve
telephone number, a transmission protocol and a proper ID code.
The principal telephone number is always called first and the reserve number is called
if no connection could be established under the principal one. If none of the two calls
is successful (either because there is no answer or because the line is busy), 4 more
attempts are made for each of them alternating the principal with the reserve number.
Every channel can be programmed so as to transmit alarm signaling or other data
using either digital protocols or pre-recorded vocal messages that are composed of
words taken from the onboard vocabulary. For digital data transmission, it is
necessary to define a digital protocol according to the kind of device (Tecnoalarm or
non-Tecnoalarm device) connected to and the ID code. The system is compatible with
the most commonly used digital protocols (see table).
SELECTION OF THE CHANNEL
+
yw
to select the channel
+
#
YES
to confirm the selection
Submenus
z
First number
Principal telephone number (max. 15 digits)
z
Second number
Reserve telephone number (max. 15 digits)
z
ID
Channel identification code needed for digital data
transmission (2 to 6 digits)
z
Format
Transmission protocol (3-digit codes - see table)
Telephone
2
PABX
Telephone
3
Channel A
Telephone
4
Channel B
Telephone
5
Channel C
Telephone
6
Channel D
Telephone
7
Channel E
Telephone
8
Channel F
Telephone
9
Channel G
Telephone
10
Channel H
Summary of Contents for TP8-64 BUS
Page 4: ...IV Installer Manual TP8 64 BUS...
Page 12: ...Index Installer Manual TP8 64 BUS 8...
Page 16: ...Generalfeatures Installer Manual TP8 64 BUS 1 4...
Page 32: ...Hardware Installer Manual TP8 64 BUS 2 16...
Page 48: ...Input expansion modules Installer Manual TP8 64 BUS 2A 16...
Page 54: ...Output expansion modules Installer Manual TP8 64 BUS 2B 6...
Page 58: ...Console Installer Manual TP8 64 BUS 2C 4...
Page 64: ...Keypoints Installer Manual TP8 64 BUS 2D 6...
Page 70: ...Programming interfaces Installer Manual TP8 64 BUS 2E 6...
Page 72: ...Telephone communicator with GSM module Installer Manual TP8 64 BUS 2F 2...
Page 82: ...Wireless expansion modules Installer Manual TP8 64 BUS 2G 10...
Page 88: ...Set up Installer Manual TP8 64 BUS 3 6...
Page 138: ...Programming by PC Installer Manual TP8 64 BUS 4 44...
Page 176: ...Programming by console Installer Manual TP8 64 BUS 5 38...
Page 180: ...Control by console Installer Manual TP8 64 BUS 6 4 OPERATIONS WITHOUT CODE...
Page 192: ...Control by console Installer Manual TP8 64 BUS 6 16...
Page 222: ...Technicalspecifications Installer Manual TP8 64 BUS 8 16...
Page 224: ...Appendix A Protocols Installer Manual TP8 64 BUS A 2...
Page 228: ...Appendix B Special procedures Installer Manual TP8 64 BUS B 2...
Page 240: ...Appendix B Special procedures Installer Manual TP8 64 BUS B 14...
Page 242: ...Appendix C Code management Installer Manual TP8 64 BUS C 2...
Page 245: ...TP8 64 BUS Installer Manual Code management Appendix C C 5...
Page 246: ...Appendix C Code management Installer Manual TP8 64 BUS C 6 TP8 64 BUS INSTALLER MANUAL...